stairways that are provided for means of escape are usually enclosed within fire resisting construction. there may be occasions when additional protection is also required for stairways.

1. what additional protective measures are available and give five example of when such additional protection would be required.
describe the difference choices of water suppliers available to the designer of an automatic sprinkler system
This question is for my class Fluid Mechanics

Fluid Mechanics

A sailboat capsizes a large distance from the shore. What might be done to: 1) correct the boat?2)Prevent this from occurring again? 3) How would this be accomplished specifically?
What are sequential circuits? Explain differences between
sequential circuits and combinational circuits
Simplify the following Boolean function:
F = A’C + A’B + AB’C + BC, using K-map?
Expand the following Boolean functions into their canonical form:
i. f(X,Y,Z)=XY+YZ+ X Z+ X Y
ii. f(X,Y,Z)=XY+ X Y + X YZ
Answer the following questions for the function f(x)= (x^3)/(x^2-9) defined on the interval [-17,15]. Enter points, such as inflection points in ascending order, i.e. smallest x values first.
A. The function f(x) has vertical asymptotes? (2 of them)
B. f(x) is concave up on the region () to () and () to ().
C. The inflection point for this function is?
hi sir hope u will fine and Good.

my Question 1 is why we use the salt and charcol for earthing?
Queston 2: what we use instead of salt and charcol for earthing?
Ques 3: how much we will use mean quantity of salt and charcol?

i am waiting sir
Reards
Majid Qayyum
write a program that reads temperature of six days and print the average temperature.
You are asked to give advice on reduction of false alarms in large, open plan areas in a factory (large machinery 10m high running along whole length of area) On investigation you find that many of the false alarm occur at the end of every shift, when the process generates dust and steam during equipment cleaning.
1. what is the likely fire detection system present which will be experiencing these problems. What is its probable purpose, Why was this detection chosen
2. suggest at-least three measures that might be taken-only in respect of the fire detection system to reduce the frequency of false alarm
3. for each measure discuss any disadvantage that might be associated with the measure and consequent qualification.The limitation or restriction that may apply with special reference to filtering measures in BS 5839-1
4. What alternative approach not using conventional fire detector but still forming part of detection system might suit this building. see commentary on choice of detection BS 5839-1 or guide