Question #69490

b) In a voltage regulator circuit, the output voltage under no load condition is 12V
while under full load it is 11.8V. Over the full range of input voltage variation the
nominal voltage output of 12V varies by 50 mV. Calculate percentage line and load
regulation.
1

Expert's answer

2017-08-15T04:16:27-0400

Answer to Question #69490, Physics / Electric Circuits

Question:

b) In a voltage regulator circuit, the output voltage under no load condition is 12V while under full load it is 11.8V. Over the full range of input voltage variation the nominal voltage output of 12V varies by 50 mV. Calculate percentage line and load regulation.

Solution:

Load regulation of constant voltage power supply is calculated as


%LR=Vminimal_loadVmaximal_loadVnominal_load100%=1211.812100%=1.67%\%LR = \frac{V_{\text{minimal\_load}} - V_{\text{maximal\_load}}}{V_{\text{nominal\_load}}} * 100\% = \frac{12 - 11.8}{12} * 100\% = 1.67\%


Line regulation can be calculated as


%LineR=ΔVnominal_load100%=0.0512100%=0.4167%\%LineR = \frac{\Delta}{V_{\text{nominal\_load}}} * 100\% = \frac{0.05}{12} * 100\% = 0.4167\%


Answer provided by AssignmentExpert.com


Need a fast expert's response?

Submit order

and get a quick answer at the best price

for any assignment or question with DETAILED EXPLANATIONS!