Question #42956

750 w electric heater plugged into 240 v power supply. A trolley passing caused insulation distort and reduced resistance between live and netral to 60 ohms.
1. what is the rate of heat production in watts
2. plug fitted carries 3 amps fuse is this correct for appliance
3. would correctly rated fuse blown as result of fault
1

Expert's answer

2014-06-02T02:30:50-0400

Answer on Question #42956-Physics-Electric Circuits

750 w electric heater plugged into 240 v power supply. A trolley passing caused insulation distort and reduced resistance between live and neutral to 60 ohms.

1. what is the rate of heat production in watts

Solution


N=U2R=240260=960 W.N = \frac {U ^ {2}}{R} = \frac {240 ^ {2}}{60} = 960 \ W.


2. plug fitted carries 3 amps fuse is this correct for appliance

Solution

This is incorrect:


Iheater=750240=3.125A>Ifuse=3A.I _ {\text {heater}} = \frac {750}{240} = 3.125 \text{A} > I _ {\text {fuse}} = 3 \text{A}.


That's why electric heater wouldn't work.

3. would correctly rated fuse blown as result of fault

Solution

Yes, correctly rated fuse would blow as result of fault because Ifault=UR=24060=4AI_{\text{fault}} = \frac{U}{R} = \frac{240}{60} = 4A is bigger than Ifusecorrect=3.125AI_{\text{fusecorrect}} = 3.125A.

http://www.AssignmentExpert.com/


Need a fast expert's response?

Submit order

and get a quick answer at the best price

for any assignment or question with DETAILED EXPLANATIONS!