Section 3: (10 marks) Word Problem

Target response size: text portion approximately 1 - 2 paragraphs (or equivalent) of explanation, plus maths portion showing your work

Four electrical devices are connected to powerpoints wired into the same electrical supply circuit. This is a standard Australian residential building circuit rated at 10 A. The devices have power ratings of 200 W, 740 W, 330 W and 1150 W. Can all four devices be operated at the same time on this circuit? 


Expert's answer

We have given the current rating i.e. 10A

We know Voltage rating in Australia = 230V

For 1st Device,

P=VIP=VI

I1=200230=0.86AI_1 = \dfrac{200}{230} = 0.86A

Similarly for the other three devices current will be

I2=3.21AI_2 = 3.21A

I3=1.43AI_3=1.43A

I4=5AI_4=5A

Total current =5+1.43+3.21+0.86=10.5A= 5+1.43+3.21+0.86 = 10.5A

Hence this value ids greater than the Rated value i.e. 10A.10A.

Hence, all four devices cannot be operated at the same time on this circuit.