According to question,

TDM system is handling the number of PAM(N)=3

Maximum input frequency of each signal (w)=5 kHz

We know that if N channel of time division multiplexed then minimum transmission bandwidth 

"B_ \nT\n\u200b\t\n =NW\\\\\n\nB_T=3\\times 5kHz =15kHz"