The induced e.m.f per phase can be calculated as follows

Armature current

Ia=S3VL=101063220=26243.19AI_a= \frac{S}{\sqrt{3}*V_L}= \frac{10*10^6}{\sqrt{3}*220} = 26243.19 A\\

Synchronous impedance,

Zs=Ra+jXs=0.07+j0.06Ω=1.90187.890ΩZ_s=R_a+jX_s = 0.07+j0.06 \Omega = 1.901\angle 87.89^0 \Omega