A salient pole synchronous generator has the following per unit parameters;xd=1.2,xq=0.8 ra=00.025. compute the excitation voltage Ef on a per unit basis,when the generator is delivering rated kva at rated voltage and at power factor of 0.8 lagging and 0.8 leading
"Xd= 1.2 pu \\newline\nXq= 0.8 pu\\newline\nRa= 0.025 pu\\newline"
As it's given that rated kva and rated voltage. We have
"Terminal\\space voltage \\space V=1pu\\newline\nArmature \\space current \\space=\\space1pu"
1) Power factor "= 0.8 lag"
This implies Power factor angle ", \\phi=cos^{-1}(0.8) = 36.87\\degree"
We have,
"Tan\\psi= \\frac{Vsin\\phi+IaXq}{Vcos\\phi+IaRa}=\\frac{0.6+0.8}{0.8+0.025}=1.697."
This implies "\\psi=Tan^{-1}(1.697) =59.49\\degree."
Load angle "(\\delta) =\\psi-\\phi=59.49-36.87=22.62\\degree"
We have,
"Id =Iasin\\psi=sin59.49=0.86\\newline Iq=Iacos\\phi= cos59. 49=0.51."
Hence Excitation voltage is,
"E= Vcos\\delta+IqRa+IdXd\\newline \nE= cos22. 62+0.51\\times 0.025+0.86\\times1.2\\newline\nE= 1.97 pu"
There fore "E\\angle\\delta=1.97\\angle22.62 pu"
2) Power factor is 0.8 lead.
This implies Power factor angle ", \\phi=cos^{-1}(0.8) = 36.87\\degree"
We have,
"Tan\\psi= \\frac{Vsin\\phi-IaXq}{Vcos\\phi+IaRa}=\\frac{0.6-0.8}{0.8+0.025}=-0.242"
This implies "\\psi=Tan^{-1}(-0.242) =-13.63\\degree."
Load angle "(\\delta) =\\psi+\\phi=-13.63+36.87=23.24\\degree"
We have,
"Id =Iasin\\psi=sin13.63=0.24\\newline Iq=Iacos\\phi= cos13.63=0.97"
Hence Excitation voltage is,
"E= Vcos\\delta+IqRa-IdXd\\newline \nE= cos23.24+0.97\\times 0.025-0.24\\times1.2\\newline\nE= 0.66pu"
There fore "E\\angle\\delta=0.66\\angle23.24pu"